Brand Name : COOLNET
Model Number : CR012
Certification : CE,ISO
Place of Origin : CHINA
MOQ : 1set
Price : 1800-30000USD
Payment Terms : T/T, L/C
Supply Ability : 300 PCS PER MONTG
Delivery Time : 10-25 working days
Packaging Details : Packed in plywooden case, standard export package
Cooling capacity : 20-50KW
Mounting : Floor Standing
Type : InRow Unit
Operating voltage : 380/400 VAC,230 VAC,220V
Warranty : 1 Year
Product name : Inrow Type Precision air conditioning
Refrigerant : R410A
Application : Data Center, IT room , Computer room, Cold/hot aisle
Color : Black/Grey
Fan type : EC fan
Power : 3N-380V-50Hz,220v/50hz/60hz
Airflow : Front Flow
Voltage : 380v/220v,220V/380V,380V/415V
In-Row Air Cooled Smart Cooling Products For Data Center(Computer Room Server Rack Cooling Unit Row-Based Cooling)
| Product Introduction Coolnet Coolrow in-row air cooled smart cooling solution adopting DC inverter compressor and high return air temperature design. It can match heat load intelligently. Coolrow series uses unique algorithm construct a precision management and intelligent O&M system, building an efficient, reliable and simple data center. The In-Row Air Conditioner is very suitable for the hot and cold aisles are closed. Feature and Benefits 
 |  | 
Scope of Application
|  | 
 | 
Air Supply Method
|  |  | 
Advantages
| The advantages mainly lie in specific applications, such as modular data centers, which do not have many advantages in ordinary computer rooms. (1) Near-end refrigeration: Close to the heat source for refrigeration, with the design of hot and cold passages, to further optimize the indoor airflow organization, reduce the overall PUE value of the computer room, and improve the cooling efficiency. (2) High energy efficiency ratio: high return air temperature and high heat output equipment have a high matching degree, which makes the unit energy efficiency ratio very good, low energy consumption and low operating cost. (3) High reliability: ultra-long life design, 24 hours and 365 days of uninterrupted operation, the average design life is about 10 years. (4) Adopt DC inverter compressor, dynamic refrigeration, high efficiency, low consumption, high adaptability; Equipped with EC centrifugal fan, N+1 redundancy design, automatically adjust the air supply volume according to the load of the computer room. (5) The size of the standard rack is consistent with the appearance of the cabinet, beautiful and easy to expand. |  | 
Technical Parameter
| Model | CRA013A | CRA020A | CRA040A | CRA050A | CRA060A | 
| Air supply | Front/Side | Front/Side | Front | Front | Front | 
| Power supply | 380VAC/3Ph/50Hz | ||||
| Cooling capacity-KW | 13.2 | 26.7 | 42.6 | 53.3 | 63.9 | 
| Sensible cooling-KW | 13.2 | 26.7 | 42.6 | 53.3 | 63.9 | 
| Compressor | |||||
| Refrigerant | R410A | ||||
| Quantity | 1 | ||||
| Fan | |||||
| Fan type | EC Centrifugal fan | ||||
| Quantity | 4 | 5 | 2 | 3 | 3 | 
| Air volume-m3/h | 3200 | 5000 | 8800 | 11000 | 12500 | 
| Heater | |||||
| Heat type | PTC | ||||
| Capacity-KW | 2 | 3 | 6 | 6 | 6 | 
| Humidification | |||||
| Capacity-KW | 1 | 1.5 | 3 | 3 | 3 | 
Certificates

Factory Details

| 
 Packing & Delivery 
 
 | 
| 
 | 
| Cases 
 | 
|   | 
| Air Cooled In Row Cooling Unit R410A For Data Center Images | 
 Data Center Air Conditioning System In Row Close-Coupled Cooling For Small To
                                                                                    
                        
                        
                        
                                                            Data Center Air Conditioning System In Row Close-Coupled Cooling For Small To
                                                    
                        
                     2000m3/H In Row Air Conditioning Unit , Precision Air Conditioner For Server
                                                                                    
                        
                        
                        
                                                            2000m3/H In Row Air Conditioning Unit , Precision Air Conditioner For Server
                                                    
                        
                     Row Based PACU Air Conditioning Unit Place Close To The Heat Source
                                                                                    
                        
                        
                        
                                                            Row Based PACU Air Conditioning Unit Place Close To The Heat Source
                                                    
                        
                     In Row Air Conditioning Unit Data Center Precision Air Conditioner
                                                                                    
                        
                        
                        
                                                            In Row Air Conditioning Unit Data Center Precision Air Conditioner
                                                    
                        
                     Data Center Rack 23.5KW Precision In Row Cooling Unit
                                                                                    
                        
                        
                        
                                                            Data Center Rack 23.5KW Precision In Row Cooling Unit
                                                    
                        
                     EC Fan In Row Air Conditioning Unit , Server Room Air Conditioning Unit
                                                                                    
                        
                        
                        
                                                            EC Fan In Row Air Conditioning Unit , Server Room Air Conditioning Unit
                                                    
                        
                     Computer Room Server Rack Cooling Unit Row-Based Cooling
                                                                                    
                        
                        
                        
                                                            Computer Room Server Rack Cooling Unit Row-Based Cooling
                                                    
                        
                     HVAC Data Centre R410A In Row Air Conditioning Unit
                                                                                    
                        
                        
                        
                                                            HVAC Data Centre R410A In Row Air Conditioning Unit
                                                    
                        
                     400VAC Data Center Precision Air Conditioner Closer To Server Rack
                                                                                    
                        
                        
                        
                                                            400VAC Data Center Precision Air Conditioner Closer To Server Rack
                                                    
                        
                     300mm Air Cooled In Row Air Conditioning Unit For Server Room
                                                                                    
                        
                        
                        
                                                            300mm Air Cooled In Row Air Conditioning Unit For Server Room